Model EPP-30V
Vibrating Wire Piezometer |
 |
EPP-30V is a vibrating wire
piezometer used to measure pore water pressure in soil,
earth/rockfills, foundations and concrete structures.
EPP-30V is of stainless steel construction, hermetically
sealed under a vacuum of 0.001 Torr. Each sensor has
built-in thermistor for temperature measurement and
surge arrestor for lightning protection. A glass to
metal seal solder pin connector is provided for easy
cable connection.
|
Specifications: |
|
Range (MPa) |
0.2, 0.3, 0.5, 0.7,
1.0, 1.5,
2.0, 3.5, 5.0 10.0, specify |
|
Accuracy |
± 0.25 % fs normal
± 0.1 % fs optional |
|
Non linearity
|
± 0.5 % fs
|
|
Over range limit
|
150 % of range |
|
Temperature limit |
-20 to 80° C |
|
Thermistor |
YSI 44005 or
equivalent |
|
Dimension (Ф x L) |
42 x 185 mm |
|
|
Model EPP-40V Vibrating Wire Slim Piezometer |
 |
EPP-40V is a small size vibrating
wire piezometer specifically designed to be used for
pore water pressure measurement in small diameter
boreholes and standpipes. It is of stainless steel
construction with built-in thermistor for temperature
measurement and surge arrestor for lightning protection.
|
Specifications: |
|
Range (MPa) |
0.35, 0.7, 1.0, 2.0 |
|
Accuracy |
± 0.2 % fs normal
± 0.1 % fs optional
|
|
Non linearity
|
± 0.5 % fs
|
|
Over range limit
|
150 % of range |
|
Temperature limit |
-20 to 80° C |
|
Thermistor |
YSI 44005 or
equivalent |
|
Dimension (Ф x L) |
19 x 100 mm |
|
Cable |
CS-0702 1m long;
specify |
|
|
Model EPP-60V
Vibrating Wire Low Pressure Piezometer |
 |
EPP-60V is a low pressure sensor extensively used for
settlement measurement and water level/water pressure
measurement in boreholes. The sensor is supplied with
vented cable
|
Specifications: |
|
Range (MPa) |
0.07 |
|
Dimension (Ф x L) |
25 x 120 mm |
|
Cable |
CS-0501 vented cable
1m long; specify
Other
specifications same as EPP-40V |
|
|
Model EPP-50V Vibrating Wire Push-in
Piezometer |
 |
EPP-50V is a push-in type vibrating
wire piezometer, designed to measure pore water pressure
in soft soil/clays and landfills. It has a pointed cone
at one end and drill rod threads at the other end. When
threaded into a drill rod, the piezometer can be pushed
into soft soil directly. The cable attached to the
piezometer is passed through the drill rod. Thread
options are EW drill rod thread or M28.
|
Specifications: |
|
Range (MPa) |
0.35, 0.7, 1.0, 2.0
|
|
Accuracy |
± 0.2 % fs normal
± 0.1 % fs optional
± 0.5 % fs |
|
Non linearity
|
± 0.5 % fs
|
|
Over range limit
|
150 % of range |
|
Temperature limit |
-20 to 80° C |
|
Thermistor |
YSI 44005 or
equivalent |
|
Dimension (Ф x L) |
35 x 166 mm |
|
|
Model EPU-20V
Vibrating Wire Uplift Pressure System |
 |
EPU-20V is a vibrating
wire uplift pressure measurement system that uses a
vibrating wire pressure sensor. It is designed for
monitoring uplift pressure of water in foundation of
dams and concrete structures. The sensor is similar to
EPP-30V except that instead of filter, a 25 mm BSP
adaptor is provided for pipe connection. A
perforated/non-perforated pipe is inserted in the
borehole, at the top of which EPU-20V is attached
through valve and fittings.
|
Specifications: |
|
Range (MPa) |
0.2, 0.3, 0.5, 1.0,
specify
|
|
Accuracy |
± 0.2 % fs normal
± 0.1 % fs optional
± 0.5 % fs |
|
Non linearity
|
± 0.5 % fs
|
|
Over range limit
|
150 % of range |
|
Temperature limit |
-20 to 80° C |
|
Thermistor |
YSI 44005 or
equivalent |
|
Dimension (Ф x L) |
42 x 210 mm |
|
|
Model EPU-20G Bourdon
Gage Type Uplift Pressure System |
|
|
EPU-20G uplift pressure measurement
system is similar to the above excepting that it
incorporates a bourdon gage with dial readout instead of
vibrating wire pressure cell that requires an electronic
readout. |
|
Model EPP-10 Porous
Tube (Casagrande) Piezometer |
 |
EPP-10 porous tube piezometer
consists of porous carborundum or allundum (casagrande)
tip, PVC standpipe, suitable adaptors and end cap.
|
Specifications: |
|
Casagrande tip
|
37 mm o.d., 25 mm i.d.,
60 cm long.
|
|
Standpipe |
20 mm o.d., 1.75 mm
wall thickness,
3 m long each. |
|
|
Model EPP-10/6 Water Level Indicator
|
 |
EPP-10/6 water level indicator is
used to measure depth of ground water in standpipes,
boreholes and wells. The unit is light in weight,
battery operated and gives accurate and quick readings
with audible signal. The tape used is a flat, high
tensile, non-stretch tape with suitable markings.
|
Specifications: |
|
Length (m) |
30, 50, 100, 150, 200, 300
|
|
Resolution |
1 mm standard
|
|
|
Model EHP–10 Twin
Tube Hydraulic Piezometer |



|
EHP-10 twin tube hydraulic piezometer
comprises of a nylon piezometer tip and ceramic filter,
connected to a wall mounted manifold system through a
polyethylene sheathed twin nylon tubing of 4 mm i.d.
filled with de-aired water. Pore pressure at tip is
measured at either or both water tubes by a vibrating
wire pressure sensor and a digital readout. The twin
tube hydraulic piezometer system is suitable for
measuring any positive pore pressure or negative pore
pressure upto (-) 5 m wc.
|
Specifications: |
|
Range (MPa) |
0.2, 0.3, 0.5, specify
|
|
Accuracy |
± 0.25 % fs normal
± 0.1 % fs optional
|
|
Over range limit
|
150 % of range |
|
Temperature limit |
-20 to 80° C |
|
Thermistor |
YSI 44005 or
equivalent |
|
Dimension (Ф x L) |
42 x 210 mm |
|
|
Model ELT-30S
Submersible Level Transmitter |
 |
ELT-30S is designed for monitoring
changes in water level in boreholes or reservoirs. The
sensor is housed in a corrosion resistant stainless
steel body and has a nylon nose cone with slanted holes
to allow water inside the sensor capsule. The signal
cable has an integral vent tube upto a range of 20m wc.
It also has high tensile strength fibre core that allows
the cable to support the weight of the level transmitter
and the length of suspension cable.
|
Specifications: |
|
Range (m wc) |
0 to 3.5, 10, 20, 35,
70, 140
|
|
Signal output
|
4-20 mA, two wire
|
|
Temperature limit |
0 to 70° C |
|
Safe over pressure
|
200 % of range |
|
Material in contact
with media |
Stainless steel AISI
304, Nitrile, Polyurethane |
|
Sealing |