Model EDI-51V Portable Vibrating Wire
Readout Unit/Data
Logger |
|
EDI-51V is used to ready any Encardio-rite vibrating wire
sensor. It can display the measured frequency in terms of time period,
frequency, frequency squared or the value of measured parameter directly
in proper engineering units. It has memory to store around 4500 readings
with date and time from upto 500 sensors. The readout unit comes with
rechargeable batteries and a suitable battery charger, RS232C serial
interface, necessary cables and manual.
|
Specifications: |
|
Frequency range |
500 Hz to 5 kHz |
|
Parameters
|
Time period, frequency, freuqency2 engineering
units |
|
Resolution |
0.01 micro-seconds |
|
Temperature measurement range |
-20 to 100° C
|
|
Temperature limit |
0 to 50° C |
|
Housing |
ABS + PU impact resistant plastic moulded housing. |
|
 |
|
Model EDI-53 Portable Readout Variable
Logger in Four
Variants |
 |
EDI-53 readout unit comes in four variants as described
below. The unit displays the measured parameter directly in applicable
engineering units. It has memory to store 3600 readings with date and
time from upto 250 sensors. Housing and accessories supplied are similar
to EDI-51V
|
Specifications: |
|
Operating Temp limit |
0 to 45° C |
|
Parameters
|
Time period, frequency, freuqency2 engineering
units |
|
|
Model EDI-53L |
EDI-53L is used for
resistive strain gage sensors including load cells.
|
Specifications: |
|
Operating Temp limit |
0 to 45° C |
|
Input |
Resistance strain gage
bridge load cell with 0 ... 3 mV/V output |
|
Excitation voltage
|
5 V DC
|
|
Preamplifier gain
|
100 |
|
|
Model EDI-53P |
Model EDI-53P is used to read potentiometric displacement
transducers with 0-2 V full scale voltage output.
|
Specifications: |
|
Operating Temp limit |
0 to 45° C |
|
Input |
0-2 V DC
|
|
Excitation voltage
|
5 V DC
|
|
|
Model EDI-53I |
EDI-53I is designed to read transducers with 4-20 mA DC
current output.
|
Specifications: |
|
Operating Temp limit |
0 to 45° C |
|
Input |
4-20 mA DC current
|
|
Input resistance
|
50 Ohm
|
|
|
Model EDI-53UTM |
Model EDI-53UTM is designed for use with Encardio-rite’s
range of uniaxial tilt meters. However, with an external switch it can
also be used with biaxial tilt sensors.
|
Specifications: |
|
Operating Temp limit |
0 to 45° C |
|
Input |
± 2 V, ± 4 V, or ± 8 V (factory configured) |
|
Excitation voltage
|
± 12 V DC
|
|
|
Model EDAS-10 Automatic Data Acquisition
System |
|
EDAS-10 delivers accurate and reliable measurements in a
variety of applications. It is most suitable for unattended or network
applications. Built around the Campbell Scientific’s middle level
programmable measurement and control module, the system includes
multiplexers, surge protectors, signal conditioners for vibrating wire
sensors, storage modules, data storage, transfer and analysing
softwares. Various options are available for connection to PC like
RS232C serial interface, short haul modems, RF modem, etc. Units are
available for upto 16/48/64/80/96/192 channels in different size
consoles.
|
Specifications: |
|
Resolution |
0.66 micro Volt (analog) |
|
Scan Rate |
Few times/sec to once/hour |
|
Power consumption
|
50 mA during measurement
|
|
Power requirement |
9.6 to 16 V DC
|
|
Storage capacity |
2 M data point, (Expandable with peripherals) |
|
Temperature limit |
-25 to + 50°C |
|
 |
|
Multiplexer
|
 |
|
Multiplexer allow a number of sensors to be measured by a
single CR1000. The EAM416 multiplexer module sequentially multiplexes 16
groups of four lines or 32 groups of two lines at a time. Compatible
sensors include vibrating wires, thermistors, thermocouples,
potentiometers, load cells, strain gages, and soil moisture blocks. |
|
Surge protector ESP-216 |
|
The input lines to the multiplexer can be protected
against lightning induced high voltage transients using the ESP-216
surge protector card. Each ESP-216 card can protect up to 16
differential channels. |
|
|
Multilogger Software
|
|
|
Multilogger software is a Windows based software for
downloading and analysing data from CR1000 EDAS-10 data acquisition
system. Each measurement channel can be configured for instrument type
and programmed to output temperature corrected data in engineering
units. Alarm limits can also be specified. The Multilogger uses the
entered information to generate an appropriate datalogger program
automatically. Multilogger includes a powerful data analysis tool
comprised of a data editor, data selector, Excel compatible spreadsheet,
report generator and charting tool.
|

 |